Counter
Output
Programs the counter outputs of the Q8 data
acquisition system.
Library
qctools
Description

The Counter Output Module for the Q8 series
of I/O cards programs one of the 32-bit general purpose counters to
output a PWM signal on an external pin. The polarity of the CNTR_EN
input may also be configured for hardware enabling/disabling of the
counter. The CNTR_EN line only affects the COUNTER clock source.
Parameters and Dialog Box

Board Number
The board number of the I/O card. If
there is only one Q8 board in your system, then the board number
should be zero. The second Q8 board in your system is board number 1,
etc.
Clock Source
The clock source to use as the
counter. If COUNTER is selected, then the PWM signal will appear on
the CNTR_OUT pin of the CONTROL header on the terminal board. If
WATCHDOG is selected, then the PWM signal will appear on the WATCHDOG
pin of the CONTROL header on the terminal board.
Period
The period in seconds of the output
signal. The period may range from 60 ns to 257 seconds (4.3 minutes),
in 60 ns units.
Pulse Width
The width of the high pulse as a
percentage of the period. The pulse width may range from 0 to 100.
CNTR_EN Polarity
Polarity of the CNTR_EN input. If this
option is not checked then the CNTR_EN is an active-low input.
Otherwise it is active-high. The CNTR_EN line has a pullup resistor
to bring it high when the input is unconnected. Hence, this option is
normally checked to enable the counter by default.
|