Measure Average PeriodMeasures the average period of a digital signal applied to the CNT input of one of the encoder DIN connectors. Libraryqctools Description
The Measure Average Period for the Q8 series of I/O cards provides a mechanism for using the 24-bit encoder counters on an installed Q8 I/O card to measure the period of a digital input signal. To use the block, connect the digital signal of interest to the A/CNT input on the DIN connector of the selected encoder input. Wire the B/DIR input high. The I/LD input is ignored and may be left unconnected. Use the power supplied on the terminal board (GND and +5V are available right on the DIN connector itself. It is recommended that they be used to wire B/DIR high by tying B/DIR to +5V). Note that the block assumes that it is invoked at the specified sampling rate, so any variation in that rate will affect the measurement. Parameters and Dialog Box |
![]() |
![]() |
||